Page 277 - ZPL II Programming Guide
P. 277

ZPL Commands    257
                                                                                                          ^SL


               ^SL


                     Set Mode and Language (for Real-Time Clock)

                              Description  The ^SL command is used to specify the Real-Time Clock’s mode of operation
                              and language for printing information.

                              Important •
                              • Time is read when the image is created. If the image stays in the queue longer than the
                                specified time the image will be recreated with a new time.
                              • There are incidents when the same time or a larger space of time may be printed on labels.
                                This is due to the format complexity and print speed.


                              Format  ^SLa,b
                              This table identifies the parameters for this format:



                               Parameters           Details
                               a = mode             Accepted Values:
                                                        S = Start Time Mode. This is the time that is read from the
                                                             Real-Time Clock when label formatting begins (when
                                                             ^XA is received). The first label has the same time
                                                             placed on it as the last label.
                                                        T = Time Now Mode. This is the time that is read from the
                                                             Real-Time Clock when the label to be printed is placed
                                                             in print queue. Time Now is similar to a serialized time
                                                             or date field.
                                                        Numeric Value = With the Enhanced Real Time Clock
                                                             (V60.13.0.10 and above) a time accuracy tolerance can
                                                             be specified. Range = 1 to 999 seconds, 0 = one second
                                                             tolerance
                                                        Example: SL30,1 = Accuracy tolerance of 30 seconds and
                                                        use English.
                                                    Default Value: S

























               9/15/06                              ZPL II Programming  Guide                  45541L-004 Rev. A