Page 281 - ZPL II Programming Guide
P. 281
ZPL Commands 261
^SO
^SO
Set Offset (for Real-Time Clock)
Description The ^SO command is used to set the secondary and the tertiary offset from the
primary Real-Time Clock.
Note • For each label only one SO2 command can be used. If more than one offset is
required, SO3 must be used.
Format ^SOa,b,c,d,e,f,g
This table identifies the parameters for this format:
Parameters Details
a = clock set Accepted Values:
2 = secondary
3 = third
Default Value: value must be specified
b = months offset Accepted Values: –32000 to 32000
Default Value: 0
c = days offset Accepted Values: –32000 to 32000
Default Value: 0
d = years offset Accepted Values: –32000 to 32000
Default Value: 0
e = hours offset Accepted Values: –32000 to 32000
Default Value: 0
f = minutes offset Accepted Values: –32000 to 32000
Default Value: 0
g = seconds offset Accepted Values: –32000 to 32000
Default Value: 0
9/15/06 ZPL II Programming Guide 45541L-004 Rev. A