                ^SX


               ^SX


                     Set ZebraNet Alert

                              Description  The ^SX command is used to configure the ZebraNet Alert System.


                              Format  ^SXa,b,c,d,e,f
                              This table identifies the parameters for this format:



                              Note • The values in this table apply to firmware V48_12_4 and above.



                               Parameters           Details
                               a = condition type   Accepted Values:
                                                        A = paper out
                                                        B = ribbon out
                                                        C = printhead over-temp
                                                        D = printhead under-temp
                                                        E = head open
                                                        F = power supply over-temp
                                                        G = ribbon-in warning (Direct Thermal Mode)
                                                        H = rewind full
                                                        I = cut error
                                                        J = printer paused
                                                        K = PQ job completed
                                                        L = label ready
                                                        M = head element out
                                                        N = reserved
                                                        O = reserved
                                                        P = power on
                                                        Q = clean printhead
                                                        R = media low
                                                        S = ribbon low
                                                        T = replace head
                                                        U = battery low
                                                        V = RFID error (in RFID printers only)
                                                        W = all errors (in RFID printers only)
                                                        * = all errors (in non-RFID printers)
                                                    Default Value: if the parameter is missing or invalid, the command
                                                    is ignored